Moment Capacity of Various Wall Thicknesses Based on Concrete Compressive Strength

6" Walls 8" Walls 10" Walls 12" Walls
4,000 psi 316 psi 20,477 in-lbs. 36,403 in-lbs. 56,880in-lbs. 81,907 in-lbs.
4,500 psi 335 psi 21,708 in-lbs. 38,592 in-lbs. 60,300 in-lbs. 86,832 in-lbs.